Control Module Temperature Sensor Performance
Control Module Temperature Sensor Circuit Low Voltage
Control Module Temperature Sensor Circuit High Voltage
For an overview of the component/system, refer to:Electronic Component Description
Component  | Description  | 
|---|---|
K71 Transmission Control Module  | The control module receives information from a variety of sensors, switches and serial data information from other control modules. This information is used to control a combination of solenoid valves to obtain the correct line pressure, gear ratio and torque converter clutch operation. K71 is part of the component:Q8 Control Solenoid Valve Assembly  | 
Control Module Temperature Sensor  | The temperature sensor is a negative temperature coefficient thermistor, a resistor which changes based on temperature. The component is part of the control module.  | 
No external circuit diagnosis is involved.
Conditions for Running the DTCP0667Frequency the DTC runs=Continuously—After the running conditions are met—For greater than 5 s
P0668, P0669Frequency the DTC runs=Continuously—After the running conditions are met—For greater than 5 s
Conditions for Setting the DTCP0667The above conditions have to be met continuously for 5 min within a 6 min period.
P0668TCM Temperature=Warmer than 253°C (488°F)—For greater than 1 min
P0669TCM Temperature=Colder than −253°C (−423°F)—For greater than 1 min
Actions Taken When the DTC SetsDTCs listed in the DTC Descriptor category=Type B DTC—Additional actions taken:
TCM Temperature=The control module uses default replacement values.—TCM Power-Up Temperature
Conditions for Clearing the DTCDTCs listed in the DTC Descriptor category=Type B DTC
Reference InformationSchematic Reference
Automatic Transmission Controls Schematics
Connector End View ReferenceMaster Electrical Component List
Electrical Information ReferencePowertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool ReferenceCircuit/System VerificationReplace the component:Q8 Control Solenoid Valve Assembly
Replace the component:Q8 Control Solenoid Valve Assembly
Verify the following parameters are within 25°C (45°F) of each other:
Replace the component:Q8 Control Solenoid Valve Assembly
Verify the DTC does not set.
Replace the component:Q8 Control Solenoid Valve Assembly
Perform the Diagnostic Repair Verification after completing the repair:Diagnostic Repair Verification