Diagnostic Instructions
DTC Descriptors
- DTC B2755
 Seat Memory Select Switch Circuit
- DTC B2765
 Seat Memory Set Switch Circuit
For symptom byte information refer to Symptom Byte List
Diagnostic Fault Information
Circuit  | Short to Ground  | Open/High Resistance  | Short to Voltage  | Signal Performance  | 
|---|
Memory Seat Switch Signal (1)  | B2755 02  | 1  | B2755 01  | B2755 59  | 
Memory Seat Switch Set Signal  | B2765 59  | 1  | —  | —  | 
Low Reference  | —  | 1  | —  | —  | 
1. Memory recall is inoperative  | 
Circuit/System Description
When a memory switch is pressed, the signal circuit from the seat memory control module is pulled low through the switch contacts and series of resistors indicating the memory recall request. In response to this signal, the seat memory control module commands the appropriate seat motors to move to the pre-recorded seat positions stored in memory.
Conditions for Running the DTC
- DTC B1327 must not be present.
 - Battery voltage must be between 9–16 V.
 
Conditions for Setting the DTC
B2755 01
If the seat memory control module detects a short to voltage on the memory seat switch signal circuit this DTC will set.
B2755 02
If the seat memory control module detects a short to ground on the memory seat switch signal circuit this DTC will set.
B2755 59
The seat memory control module detects a stuck Memory 1, Memory 2, or Exit switch for a given amount of time.
B2765 59
If the memory set switch signal is active for greater than 15 s this DTC will set.
Actions Taken When the DTC Sets
- Current and history codes are set.
 - All memory recall commands and are ignored.
 
Conditions for Clearing the DTCs
- The DTC automatically clears when the switch circuit setting the DTC is no longer active.
 - A history DTC will clear once 50 consecutive fault-free ignition cycles have occurred.
 
Reference Information
Schematic ReferenceDriver Seat Schematics
Connector End View ReferenceMaster Electrical Component List
Description and OperationMemory Seats Description and Operation
Electrical Information ReferenceScan Tool ReferenceControl Module References for scan tool information
Circuit/System Verification
- Ignition ON.
 - Verify the scan tool Seat Memory Control Module Memory Recall Switches parameter changes between Inactive and Memory 1 when pressing the memory 1 switch.
 - Verify the scan tool Seat Memory Control Module Memory Recall Switches parameter changes between Inactive and Memory 2 when pressing the memory 2 switch.
 - Verify the scan tool Seat Memory Control Module Memory Recall Switches parameter changes between Inactive and Exit when pressing the EXIT switch.
 - Verify the scan tool Memory Recall Switches parameter changes between Inactive and Active when pressing the SET switch.
 - All OK.
 
Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the S47D Seat Memory Switch – Driver.
 - Ignition ON, press a power seat switch in order to wake up the K40D Seat Memory Control Module – Driver.
 - Test for 9 V or greater between each signal circuit terminal listed below and ground:
 - Memory set switch signal terminal 5
 - Memory switch signal terminal 6
 
- Ignition OFF, disconnect the X6 harness connector at the K40D Seat Memory Control Module – Driver.
 - Test for infinite resistance between the signal circuit and ground.
 - If less than infinite resistance, repair the short to ground on the circuit.
 
- Test for less than 2 Ω in the signal circuit end to end.
 - If 2 Ω or greater, repair the open/high resistance in the circuit.
 - If less than 2 Ω, replace the K40D Seat Memory Control Module – Driver.
 
- Ignition OFF, disconnect the X6 harness connector at the K40D Seat Memory Control Module – Driver, ignition ON.
 - Test for less than 1 V between each signal circuit terminal listed below and ground:
 - Memory set switch signal terminal 5
 - Memory switch signal terminal 6
 
- Test or replace the S47D Seat Memory Switch – Driver.
 
Component Testing
Driver Seat Memory Switch: - Ignition OFF, disconnect the harness connector at the S47D Seat Memory Switch – Driver.
 - Test for infinite resistance between the ground terminal 1 and each signal terminal listed below with the switch in the open position.
 - Test for less than 4 Ω between the signal terminal 5 and the ground terminal 1 while pressing the memory SET button.
 - Test for 570–697 Ω between the signal terminal 6 and the low reference terminal 1 while pressing the Memory 1 button.
 - Test for 1800–2201 Ω between the signal terminal 6 and the low reference terminal 1 while pressing the Memory 2 button.
 - Test for 5.25k–673 kΩ between the signal terminal 6 and the low reference terminal 1 while pressing the Exit button.
 - All OK.
 