Diagnostic Instructions
DTC Descriptors
Ambient Air Temperature Sensor Circuit Short to Ground
Ambient Air Temperature Sensor Circuit High Voltage/Open
Diagnostic Fault Information
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
Signal | B0158 02 | B0158 05 | B0158 05 | — |
Low Reference | — | B0158 05 | — | — |
Circuit/System Description
The instrument cluster monitors the ambient air temperature sensor with a low reference circuit and signal circuit. The instrument cluster monitors the voltage drop across the sensor, which is inversely proportional to temperature. When the ambient air temperature is cold, the resistance of the sensor is high. When the ambient air temperature is warm, the resistance of the sensors is low. The instrument cluster converts the voltage value to a temperature value and displays the temperature.
Conditions for Running the DTC
The system voltage is between 9–16 V.
Conditions for Setting the DTC
B0158 02
The instrument cluster detects the sensor signal is more than 88°C (190°F) .
B0158 05
The instrument cluster detects the sensor signal is less than −40°C (−40°F).
Action Taken When the DTC Sets
The instrument cluster uses a default air temperature value for further calculations. The instrument cluster will display −°C (−°F).
Conditions for Clearing the DTC
The DTC will become history if the instrument cluster no longer detects a malfunction.
Reference Information
Schematic ReferenceConnector End View ReferenceDescription and OperationInstrument Cluster Description and Operation
Electrical Information ReferenceControl Module References for scan tool information
Circuit/System Testing
Repair Instructions
Perform the Diagnostic Repair Verification after completing the repair.