Liftgate Control Module Scan Tool Information
Liftgate Module Scan Tool Data Parameters

Parameter

Expected Value

Description

Operating Conditions: Ignition ON

In Park Switch Status

On/Off

The scan tool displays Off or On. On is displayed if the vehicle was in Park during the last open or close history data.

Liftgate Ajar Switch

Open/Closed

The scan tool displays Open or Closed. This was the last state of the liftgate ajar switch in the open or close history data.

Liftgate Angle

0° - 80°

The scan tool displays the calculated angle in degrees of the liftgate relative to the liftgate latch.

Liftgate Disable Switch

Varies

The scan tool displays 123, 337, or 238 counts. when the rotary switch of the interior liftgate control switch is selected to the Off, ¾ or Max position.

Liftgate Front Control Switch

Active/Inactive

The scan tool displays Active or Inactive. This is the state of the front control switch of the liftgate module.

Liftgate Handle Switch

Active/Inactive

The scan tool displays Active or Inactive. This is the state of the liftgate handle switch.

Liftgate Latch Pawl Switch

Open/Closed

The scan tool displays Open or Closed. This is the state of the latch pawl switch.

Liftgate Latch Ratchet Switch

Open/Closed

The scan tool displays Open or Closed. This is the state of the latch ratchet switch.

Liftgate Latch Sector Switch

Inactive

The scan tool will display Inactive to Active to Inactive as the liftgate unlatches. This is the state of the latch sector switch.

Liftgate Open/Closed Position Learned

Yes

The scan tool displays Yes or No. This is the state of the liftgate module open/close position programming.

Liftgate System Voltage 1

11.5–13.0 V

The scan tool displays the battery system 1 voltage input to the liftgate module.

Liftgate System Voltage 2

11.5–13.0 V

The scan tool displays the battery system 2 voltage input to the liftgate module.

Liftgate Rear Close Switch

Active/Inactive

The scan tool displays Active or Inactive. This is the state of the liftgate close switch.

Secondary Obstacle Detection Voltage

3–3.5 V

The scan tool displays the actual voltage on the liftgate object sensors circuit as measured by the liftgate control module.